C282 – ISO 5167/McCrometer Cone Calculations
Description
This calculation can be set to calculate the flow rate through an cone based metering system, the differential pressure setting of the metering system or the cone size to use for specified flowing conditions using the ISO 5167 standard as a guideline alongside McCrometer technical publications.
References
24509-54 Flow Calculations for the V-Cone and Wafer-Cone Flow meters – McCrometer
24517-16 V-Cone Flow Meter Technical Brief – McCrometer
ISO 5167 – Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full
ISO TR9464 – Guidelines for the use of ISO 5167
Kelton calculation reference C282
FLOCALC calculation reference F070
KIMS calculation reference K217
Kelton calculation reference C272 – Cone Meter Mass Flow Calculation
Kelton calculation reference C273 – ISO 5167 Differential Pressure Calculations
Kelton calculation reference C274 – ISO 5167 Sizing Calculation
Kelton calculation reference C261 – Gas Flowrate Conversion from Qm
Kelton calculation reference C262 – Liquid Flowrate Conversion
Options
Option group name
- Flow rate
- Cone diameter
- Differential pressure
This option is used to select what kind of calculation the user wishes to implement.
Cone Type
- V-Cone
- Wafer-Cone
This option is used to select which set of equations to apply to the cone whether it be those associated with the v-cone or the wafer cone flow meter.
The rest of the options that can be encountered in this calculation can be found in the calculations referenced above.
Calculation
Mass Flow Rate
The mass flow rate is calculated using the formula shown in C272. Further flow rate outputs, if required, are calculated using one of the flow rate converters using this value of mass flow rate.
Cone Diameter
The cone diameter is calculated according to the process described in C274.
Differential Pressure
The differential pressure is solved as described in C273.