Rosemount 1151 Differential Pressure Transmitter

Type Data source
1151DP Smart Product Data Sheet 00813-0100-4360, Rev JB Catalog March 2010
1151DP Analogue Product Data Sheet 00813-0100-4360, Rev JB Catalog March 2010
1151HP Smart Product Data Sheet 00813-0100-4360, Rev JB Catalog March 2010
1151HP Analogue Product Data Sheet 00813-0100-4360, Rev JB Catalog March 2010

N.B. In the Specifications, the below image is a guide on what output code to use:

Reference Accuracy U(ac)

1151DP Smart

Ranges 3-8 for spans less than 10:1
± 0.075% of span
for spans from 10:1 to 50:1
All other Ranges ± 0.25% of span for all spans

1151DP Analogue

Ranges 3-5 ± 0.2% of span for all spans <10 in H2O
Ranges 3-8 ± 0.1% of span for all spans >10 in H2O
All other Ranges ± 0.25% of span for all spans

1151HP Smart

Ranges 4-7 for spans less than 10:1
± 0.075% of span
for spans from 10:1 to 50:1
All other Ranges ± 0.25% of span for all spans

1151HP Analogue

Ranges 3-8 ± 0.1% of span for all spans >10 in H2O
All other Ranges ± 0.25% of span for all spans

Drift (stability) U(d)

1151DP & HP Smart

Ranges 3-8 ± 0.1% of URL for 2 years
All Other Ranges ± 0.25% of URL for 6 months

1151DP & HP Analogue

Ranges 3-6 ± 0.2% of URL for 6 months
All Other Ranges ± 0.25% of URL for 6 months

Power supply effect U(ps)

All Models

Less than ± 0.005% of calibrated span per volt change.

Ambient temperature effect U(ac)

1151DP & HP Smart

Zero Error Total Error
Ranges 4-8 ± 0.2% of URL per 56°C ±(0.2% URL + 0.18% Span) per 56°C
All Other Ranges double the effect double the effect

1151DP & HP Analogue

Zero Error Total Error
Ranges 4-0 ± 0.5% of URL per 56°C ±(0.5% URL + 0.5% Span) per 56°C
Range 3 double the effect double the effect

 

 

Back