PMC71 Endress & Hauser Pressure Transmitter
Type | Data source |
---|---|
PMC71 Standard | Product Data Sheet 2.5M309CW 2012 |
PMC71 Platinum | Product Data Sheet 2.5M309CW 2012 |
Reference Accuracy U(ac)
Standard
Range | Sensor | Low Turndown | High Turndown |
---|---|---|---|
100 mbar 250 mbar |
Gauge Gauge & Absolute |
1:1 to 10:1 ± 0.075% |
> 10:1 |
100 mbar | Absolute | 1:1 to 5:1 ± 0.075% |
> 5:1 |
All other ranges | Gauge & Absolute | 1:1 to 10:1 ± 0.05% |
> 10:1
|
Platinum
Range | Sensor | U(ac) |
---|---|---|
100 mbar & 250 mbar | Gauge & Absolute | ± 0.05% |
400 mbar & 1 bar 2 bar & 4 bar 10 bar & 40 bar |
Gauge & Absolute Gauge Gauge & Absolute |
± 0.035% |
2 bar & 4 bar | Gauge | ± 0.025% |
Drift (stability) U(d) =
Standard
Range | Sensor | Stability |
---|---|---|
1 bar | Gauge & Absolute | ± 0.05% of URL for 1 year |
All other ranges | Gauge | ± 0.2% of URL for 10 years |
All other ranges | Absolute | ± 0.3% of URL for 10 years |
Platinum
± 0.1% of URL for 1 year
Power supply effect U(ps)
± 0.0006% of calibrated span per volt change.
Ambient temperature effect U(ac)
Standard
Range | -10°C to 60°C | -20°C to -10°C 60°C to 125°C |
---|---|---|
100, 250 & 400 mbar | ||
All other ranges |
Platinum
Gauge
Range | -10°C to 60°C | 60°C to 150°C |
---|---|---|
100, 250 & 400 mbar | ||
All other ranges |
Absolute
Range | -10°C to 60°C | 60°C to 150°C |
---|---|---|
100 mbar | ||
250 & 400 mbar | ||
40 bar | ||