PMC71 Endress & Hauser Pressure Transmitter

Type Data source
PMC71 Standard Product Data Sheet 2.5M309CW 2012
PMC71 Platinum Product Data Sheet 2.5M309CW 2012

Reference Accuracy U(ac)

Standard

Range Sensor Low Turndown High Turndown
100 mbar
250 mbar
Gauge
Gauge & Absolute
1:1 to 10:1
± 0.075%
> 10:1

100 mbar Absolute 1:1 to 5:1
± 0.075%
> 5:1
All other ranges Gauge & Absolute 1:1 to 10:1
± 0.05%
> 10:1

Platinum

Range Sensor U(ac)
100 mbar & 250 mbar Gauge & Absolute ± 0.05%
400 mbar & 1 bar
2 bar & 4 bar
10 bar & 40 bar
Gauge & Absolute
Gauge
Gauge & Absolute
± 0.035%
2 bar & 4 bar Gauge ± 0.025%

Drift (stability) U(d) =

Standard

Range Sensor Stability
1 bar Gauge & Absolute ± 0.05% of URL for 1 year
All other ranges Gauge ± 0.2% of URL for 10 years
All other ranges Absolute ± 0.3% of URL for 10 years

Platinum

± 0.1% of URL for 1 year

Power supply effect U(ps)

± 0.0006% of calibrated span per volt change.

Ambient temperature effect U(ac)

Standard

Range -10°C to 60°C -20°C to -10°C
60°C to 125°C
100, 250 & 400 mbar
All other ranges

Platinum

Gauge

Range -10°C to 60°C 60°C to 150°C
100, 250 & 400 mbar
All other ranges


Absolute

Range -10°C to 60°C 60°C to 150°C
100 mbar
250 & 400 mbar
40 bar
All other ranges

 

 