Honeywell ST3000 Pressure Transmitter
Type | Data source |
---|---|
100 | Product Data Sheet 34-ST-03-62 Catalog January 2006 |
100HT | Product Data Sheet 34-ST-03-70 Catalog January 2006 |
900 | Product Data Sheet 34-ST-03-67 Catalog January 2006 |
Reference Accuracy U(ac)
100
Analogue Mode
Range | Low Turndown | High Turndown |
---|---|---|
19L | ± 0.075% of calibrated span | |
All other ranges | ± 0.075% of calibrated span |
100HT
Analogue Mode
Range | Low Turndown | High Turndown |
---|---|---|
14T | ± 0.0875% of calibrated span |
900
Analogue Mode
Range | Low Turndown | High Turndown |
---|---|---|
944 & 94L | ± 0.075% of calibrated span | |
All other ranges | ± 0.1% of calibrated span |
Drift (stability) U(d)
100
Range | |
---|---|
140 & 14L | ± 0.015% of URL for 1 year |
All other ranges | ± 0.03% of URL for 1 year |
100HT
± 0.04% of URL for 1 year
900
Range | |
---|---|
944 & 94L | ± 0.015% of URL for 1 year |
All other ranges | ± 0.03% of URL for 1 year |
Power supply effect U(ps)
All Models
Less than ± 0.005% of calibrated span per volt change.
Ambient temperature effect U(ac)
100
Analogue Mode
Range | Low Turndown | High Turndown |
---|---|---|
140 & 14L | ± 0.1% of calibrated span | |
All other ranges | ± 0.175% of calibrated span |
100HT
Analogue Mode
Range | Low Turndown | High Turndown |
---|---|---|
14T | ± 0.1% of calibrated span |
900
Analogue Mode
Range | Low Turndown | High Turndown |
---|---|---|
944 & 94L | ± 0.25% of calibrated span | |
All other ranges | ± 0.325% of calibrated span |