C296 – GPA TP-27 – NGL and LPG Density Referral
Description
This calculates the density of an NGL or LPG at standard conditions or at process temperature and pressure using the guidelines set out in the below GPA and API standards.
References
GPA TP-27/API MPMS Chapter 11.2.4 – Temperature Correction for the Volume of NGL and LPG – Tables 23E, 24E, 53E, 54E, 59E and 60E (2007)
API MPMS Chapter 11.2.2M – Compressibility Factors for Hydrocarbons: 350 – 637 Kilograms per Cubic Metre Density (15°C) and -46°C to 60°C Metering Temperature (1986)
API MPMS Chapter 11.1 – Temperature and Pressure Volume Correction Factors for Generalized Crude Oils, Refined Products and Lubricating Oils w/Addendum (2007)
Kelton calculation reference C296
FLOCALC calculation reference F092
Options
Solve for
- Density
- Standard density
This option is used to select whether the calculation will solve for density at process or standard conditions.
Precision
- Full precision
- Full rounding
- Rounding of inputs
This option is used to decide upon the rounding procedure to be employed. The full precision calculation doesn’t round any values. Full rounding rounds the inputs and outputs as described in the relevant standards. Rounding of inputs only rounds the input temperature and density according to the procedure set out in GPA TP-27. Note that the range of the density inputs at standard conditions vary from one standard temperature to another. Consult the relevant standards for details of the range of the input parameters of the calculation as the ranges associated with standards used in this procedure do not overlap at all temperatures and densities. Note that when rounding is used for certain input values the calculation does not converge, this issue is overcome by selecting full precision. An intermediate will be displayed to show whether the calculation has converged sufficiently.
Vapour Pressure
- Include
Select this option to include vapour pressure input. If this is not selected the calculation will use a default value of 1 atmosphere (1.01325 bar).
Standard Temperature
- 15°C
- 20°C
- 60°F
This option is used to select the standard temperature at which the fluid is being metered against.
API Compressibility
- Metric
- US Customary
This option is used to select whether the pressure correction is to use the metric versions of API compressibility standards, MPMS Chapters 11.2.1M or 11.2.2M, or the standards in US customary units 11.2.1 and 11.2.2.
Calculation
The calculation is carried out as detailed in C294.