C284 – ISO 5167/McCrometer Wet Gas V-Cone Totalisation (Steven)
Description
This calculates the totals for a wet gas v-cone based metering system according to the ISO 5167 standard and relevant McCrometer technical publications.
References
ISO 5167 – Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full
ISO TR 9464 – Guidelines for the use of ISO 5167
24509-54 Flow Calculations for the V-Cone and Wafer-Cone Flow meters – McCrometer
24517-16 V-Cone Flow Meter Technical Brief – McCrometer
Wet Gas Metering with V-Cone Meters – R Steven, RJW Peters, D Hodges, D Stewart
Kelton calculation reference C284
FLOCALC calculation reference K235
Options
The options that are available to the user are derived from C283 – ISO 5167/McCrometer Wet Gas V-Cone Flow Calculation (Steven) and C203 – Totalisation Conversion.
Calculation
The calculations involved in C292 are derived from C283 – ISO 5167/McCrometer Wet Gas V-Cone Flow Calculation (Steven) and C203 – Totalisation Conversion.