Autrol APT3100 Pressure Transmitter
| Type | Data source |
|---|---|
| 3100 | Product Data Sheet C3100-E01B |
Reference Accuracy U(ac)
| Range | for 0.1URL < Span < URL | for 0.01URL < Span < 0.1URL |
|---|---|---|
| 3 to 7 | ± 0.075% of span | |
| All other ranges | ± 0.1% of span | ![]() |
Drift (stability) U(d)
± 0.125% of URL for 1 year
Power supply effect U(ps)
± 0.005% of calibrated span per volt change.
Ambient temperature effect U(ac)
| Span < 10% of URL | Span > 10% of URL |
|---|---|
| ±(0.019% URL + 0.125% Span) | ±(0.025% URL + 0.125% Span) |