ABB 2600T/266 Pressure Transmitter
Type | Data source |
---|---|
266HSH | Product Data Sheet DS/266HSH/NSH-EN Rev. H 2014 |
266NSH | Product Data Sheet DS/266HSH/NSH-EN Rev. H 2014 |
266GST | Product Data Sheet DS/266GST/AST-EN Rev. F 032021 |
266AST | Product Data Sheet DS/266GST/AST-EN Rev. F 032021 |
Reference Accuracy U(ac)
266HSH
Range | Low Turndown | High Turndown |
---|---|---|
G to Q | For spans less than 10:1 ± 0.06% of calibrated span |
For spans greater than 10:1 |
E, S & V | For spans less than 10:1 ± 0.075% of calibrated span |
For spans greater than 10:1
|
Z | For spans less than 5:1 ± 0.15% of calibrated span |
For spans greater than 5:1
|
266NSH
Range | Low Turndown | High Turndown |
---|---|---|
G to S | For spans less than 10:1 ± 0.075% of calibrated span |
For spans greater than 10:1
|
266GST
Range | Low Turndown | High Turndown |
---|---|---|
C to V |
For spans less than 10:1 High Accuracy option ± 0.025% of calibrated span |
For spans greater than 10:1 |
L to R |
For spans less than 10:1 High Accuracy option ± 0.025% of calibrated span |
|
|
266AST
Range | Low Turndown | High Turndown |
---|---|---|
G to S | For spans less than 10:1 ± 0.04% of calibrated span |
For spans greater than 10:1
|
Drift (stability) U(d)
266HSH & 266NSH
Ranges E to V | ± 0.15% of URL for 10 years |
---|---|
Range Z | ± 0.45% of URL for 3 years |
266GST & 266AST
All Ranges | ± 0.15% of URL for 10 years |
---|---|
Power supply effect U(ps)
266HSH & 266NSH
± 0.001% of URL per volt change.
266GST & 266AST
± 0.005% of URL per volt change.
Ambient temperature effect U(ac)
Per 20K change
266HSH
Range | For turndown up to 10:1 |
---|---|
G to Q | ±(0.03% URL + 0.045% Span) |
E, S & V | ±(0.04% URL + 0.065% Span) |
Z | ±(0.06% URL + 0.1% Span) |
266NSH
Range | For turndown up to 10:1 |
---|---|
G to Q | ±(0.06% URL + 0.09% Span) |
S | ±(0.08% URL + 0.13% Span) |
266GST & 266AST
Range | For turndown up to 10:1 |
---|---|
C and F | ±(0.06% URL + 0.09% Span) |
L to V | ±(0.03% URL + 0.045% Span) |