C132 – Sampler Control Pulse Check
Description
This calculates the number of pulses expected for a volume or mass at a given pulse significance factor.
References
Kelton calculation reference C132
KIMS calculation reference K162
Options
Sampler type
- Volume based
This option is chosen to perform the volume based calculation.
- Mass based
This option is chosen to perform the mass based calculation.
Calculation
Corrected something
When using the volume based method the number of pulses is calculated by:
Where | ||
---|---|---|
VE | = | Total volume at the end |
VS | = | Total volume at the start |
VP | Pulse significance factor |
When using the mass based method the number of pulses is calculated by:
Where | ||
---|---|---|
ME | = | Total mass at the end |
MS | = | Total mass at the start |
MP | Pulse significance factor |