C053 – Gas Totalisation – Pulse Output Meter

Description

This calculates the totals for pulse output based meters where the metered fluid is a gas.

References

IP Petroleum Measurement Manual Part Ⅻ – Static and Dynamic Measurement of Light Hydrocarbon Liquids – Section 1: Calculation Procedures

AGA 7 – Measurement of Natural Gas by Turbine Meters (2006)

Kelton calculation reference C053

KIMS calculation reference K135

Kelton Calculation C203 – Totalisation Conversion

Kelton Calculation C264 – Flow Rate – Pulse Output Meter

Options

Method

  • Injected frequency
  • Injected pulses

This option is used to select whether the total will be calculated from the flow rate if frequency is chosen or calculated directly using the number of pulses measured.

Enter elapsed time as

  • Duration
  • Start and end time

This option is used to select whether the time over which the totals are to be calculated is entered as a duration or as a start and end time.

Totals

  • Use start and end totals

This option allows the user to enter displayed totals for the start and end of the totalisation process for comparison with the calculated results.

The remaining options are the same as are found in K133 – Gas Flow Rate – Pulse Output Meter

Calculation

Duration

If the duration is calculated this is done by:

Where
t1 = End time
t0 = Start time

Totals

If injected pulses is selected the totals are calculated from the equation:


If injected frequency is selected the totals are calculated from flow rate by:

Where
IntF = Interpolation factor
MF = Meter Factor
Inj_pulses = Injected pulses
Kf = K-factor
Ctsm = Correction for temperature on steel of meter
Cpsm = Correction for pressure on steel of meter
Q = Flow rate
t = Duration

 

 